Quick view S+S | sku: 1201-7131-0000-101 HYGRASGARD® AFF-25-U Calibratable HYGRASGARD® AFF-25 / AFTF-25 (± 1,8%) with pluggable measuring head and metal sinter filter, housing made of impact resistant plastic with quick-locking screws, optionally with/without display, and with cable gland or optional M12 connector... Log in for pricing Compare
Quick view S+S | sku: 1201-7132-0000-101 HYGRASGARD® AFF-25-I Calibratable HYGRASGARD® AFF-25 / AFTF-25 (± 1,8%) with pluggable measuring head and metal sinter filter, housing made of impact resistant plastic with quick-locking screws, optionally with/without display, and with cable gland or optional M12 connector... Log in for pricing Compare
Quick view S+S | sku: 2003-6122-1100-001 HYGRASGARD® AFTF-20-U Q LCD Calibratable HYGRASGARD® AFF-20 / AFTF-20 (± 1,8%) outside humidity/temperature transmitters with plastic sinter filter (metal sinter filter optional); housing made of impact resistant plastic, with quick-locking screws, optionally with/without display,... Log in for pricing Compare
Quick view S+S | sku: 2003-6122-2100-001 HYGRASGARD® AFTF-20-I Q LCD Calibratable HYGRASGARD® AFF-20 / AFTF-20 (± 1,8%) outside humidity/temperature transmitters with plastic sinter filter (metal sinter filter optional); housing made of impact resistant plastic, with quick-locking screws, optionally with/without display,... Log in for pricing Compare
Quick view S+S | sku: 2003-4172-1100-001 HYGRASGARD® KFTF-20-U Q LCD Calibratable HYGRASGARD® KFF - SD / KFTF - SD duct humidity/temperature transmitters (± 2,0%), with plastic sinter filter (metal sinter filter optional), housing made of impact resistant plastic with snap-on cover, with cable gland (or optional M12... Log in for pricing Compare
Quick view S+S | sku: 2003-4172-2100-001 HYGRASGARD® KFTF-20-I Q LCD Calibratable HYGRASGARD® KFF - SD / KFTF - SD duct humidity/temperature transmitters (± 2,0%), with plastic sinter filter (metal sinter filter optional), housing made of impact resistant plastic with snap-on cover, with cable gland (or optional M12... Log in for pricing Compare
Quick view S+S | sku: 1301-4122-0560-000 PREMASGARD® SHD 692-I-930 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4122-0550-000 PREMASGARD® SHD 692-I-919 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4122-0540-000 PREMASGARD® SHD 692-I-918 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4122-0530-000 PREMASGARD® SHD 692-I-916 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4122-0520-000 PREMASGARD® SHD 692-I-912 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4122-0510-000 PREMASGARD® SHD 692-I-907 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4122-0500-000 PREMASGARD® SHD 692-I-900 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4121-0560-000 PREMASGARD® SHD 692-U-930 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4121-0550-000 PREMASGARD® SHD 692-U-919 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4121-0540-000 PREMASGARD® SHD 692-U-918 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4121-0530-000 PREMASGARD® SHD 692-U-916 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4121-0520-000 PREMASGARD® SHD 692-U-912 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4121-0510-000 PREMASGARD® SHD 692-U-907 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1301-4121-0500-000 PREMASGARD® SHD 692-U-900 The PREMASGARD® SHD-692 differential pressure transducer serves to measure pressures in gaseous and liquid media. It converts the measurand into standard signals of 0?-10 V or 4...20mA. Process connection is 2x G??"?-?27 NPT internal thread.The SHD?-692... Log in for pricing Compare
Quick view S+S | sku: 1201-6131-1000-100 HYGRASGARD® DFTF-U The calibratable HYGRASGARD® DFF / DFTF humidity and temperature transmitter measures the relative humidity and temperature of air. It converts the measurands into a standard signal of 0-10 V or 4...20 mA, and is available with/without optional display... Log in for pricing Compare
Quick view S+S | sku: 1201-6132-1000-100 HYGRASGARD® DFTF-I The calibratable HYGRASGARD® DFF / DFTF humidity and temperature transmitter measures the relative humidity and temperature of air. It converts the measurands into a standard signal of 0-10 V or 4...20 mA, and is available with/without optional display... Log in for pricing Compare
Quick view RESI | sku: RESI-ENO-ETH Ethernet gateway ENOCEAN-868MHz-MODBUS/TCP server,ASCII text socket, 10/100MBit Ethernet, incl. antenna, EU Connects a host with MODBUS/TCP or ASCII text socket protocol to an ENOCEAN radio system, Radio standard ENOCEAN 868Mhz ISO/IEC 14543-3-10, Host communication: via 10/100MBit Ethernet, gateway protocol is MODBUS/TCP server or ASCII text socket, ENOCEAN... Log in for pricing Compare
Quick view RESI | sku: RESI-12AOU-SIO BIG IO module, 8TE, module with 12 analogue inputs for -10Vdc..+10Vdc or 0..10Vdc voltage signals, RS485, MODBUS/RTU slave, ASCII text commands, 12-48V= MODBUS/RTU module with 12 analogue inputs for -10Vdc..+10Vdc or 0..10Vdc voltage signals, each analog signal on own 2pin terminal block, host communication: via RS485 with MODBUS/RTU slave protocol, Host baud rates: 4800, 9600, 19200, 38400, 57600,... Log in for pricing Compare
Quick view S+S | sku: 1201-1276-1000-101 HYGRASGARD® RPFTF-20-Modbus Quality products for the HVAC sector, accuracy ±1.8% or ±2%Calibratable HYGRASGARD® AFTF?-SD?-?Modbus or RPFTF - 20 - Modbus room pendulum humidity and temperature transmitters with ±1.8% or ±2% accuracy, respectively, as well as plastic sinter filter... Log in for pricing Compare
Quick view S+S | sku: 1201-6131-0000-100 HYGRASGARD® DFF-U The calibratable HYGRASGARD® DFF / DFTF humidity and temperature transmitter measures the relative humidity and temperature of air. It converts the measurands into a standard signal of 0-10 V or 4...20 mA, and is available with/without optional display... Log in for pricing Compare
Quick view S+S | sku: 1201-6132-0000-100 HYGRASGARD® DFF-I The calibratable HYGRASGARD® DFF / DFTF humidity and temperature transmitter measures the relative humidity and temperature of air. It converts the measurands into a standard signal of 0-10 V or 4...20 mA, and is available with/without optional display... Log in for pricing Compare
Quick view S+S | sku: 1201-1276-1200-000 HYGRASGARD® RPFTF-Modbus LCD Quality products for the HVAC sector, accuracy ±1.8% or ±2%Calibratable HYGRASGARD® AFTF?-SD?-?Modbus or RPFTF - 20 - Modbus room pendulum humidity and temperature transmitters with ±1.8% or ±2% accuracy, respectively, as well as plastic sinter filter... Log in for pricing Compare
Quick view S+S | sku: 1201-624F-1000-000 HYGRASGARD® RPFTF-wModbus Calibratable room pendulum humidity and temperature sensor HYGRASGARD® RPFTF - Modbus - T3 (± 2,0 %) or RPFTF - 20 - Modbus - T3 (± 1,8 %), with Modbus connection, in an impact-resistant plastic housing with quick-locking screws, optionally with ?... Log in for pricing Compare
Quick view RESI | sku: RESI-8RTD-SIO BIG IO module, 8TE, module with 8 temperature inputs for RTD sensor elements: PT100, PT200, PT500, PT1000, NI120, NI1000-DIN43760. 2 wire, 3 wire or 4 wire connection of sensorelement, RS485, MODBUS/RTU slave, ASCII text commands, 12-48V= MODBUS/RTU or ASCII module with 8 temperature inputs for RTD sensor elements: PT100, PT200, PT500, PT1000, NI120, NI1000-DIN43760. 2 wire, 3 wire or 4 wire connection of sensor element, host communication: via RS485 with MODBUS/RTU slave protocol or... Log in for pricing Compare
Quick view S+S | sku: 2004-6332-B100-021 PREMASGARD 7225 Q LCD Patented quality product (patent no. DE 10 2015 015 941 B4)Calibratable PREMASGARD® 722x dual pressure transmitter (series) with 2x 8 switchable measuring ranges, 2 automated output signals (32 devices in one), housing with pressure connection nozzle... Log in for pricing Compare
Quick view S+S | sku: 2004-6332-B100-011 PREMASGARD 7227 Q LCD Patented quality product (patent no. DE 10 2015 015 941 B4)Calibratable PREMASGARD® 722x dual pressure transmitter (series) with 2x 8 switchable measuring ranges, 2 automated output signals (32 devices in one), housing with pressure connection nozzle... Log in for pricing Compare
Quick view S+S | sku: 2004-6332-B100-001 PREMASGARD 7229 Q LCD Patented quality product (patent no. DE 10 2015 015 941 B4)Calibratable PREMASGARD® 722x dual pressure transmitter (series) with 2x 8 switchable measuring ranges, 2 automated output signals (32 devices in one), housing with pressure connection nozzle... Log in for pricing Compare
Quick view RESI | sku: RESI-8SB-SIO BIG IO module, 8TE, module for 8 shutters or blinds, RS485, MODBUS/RTU slave, 12-48V= MODBUS/RTU module for 8 shutters or blinds, each shutter or blind on its own 3-pin connector, combined 230V supply for all 8 shutters or blinds via 2-pin connector, Relays: AgNi, max. 250Vac, max. 6A, host communication: via RS485 with MODBUS/RTU slave... Log in for pricing Compare
Quick view S+S | sku: 1301-7112-4370-200 PREMASGARD 7112-I LCD The calibratable pressure sensors PREMASGARD® 711x (series) with eight switchable measuring ranges (eight devices in one), housing made from impact-resistant plastic, optionally with ? without display, with cable gland or M12 connector according to DIN... Log in for pricing Compare
Quick view S+S | sku: 1301-7111-4370-200 PREMASGARD 7112-U LCD The calibratable pressure sensors PREMASGARD® 711x (series) with eight switchable measuring ranges (eight devices in one), housing made from impact-resistant plastic, optionally with ? without display, with cable gland or M12 connector according to DIN... Log in for pricing Compare
Quick view S+S | sku: 2004-6132-4100-031 PREMASREG 7165-UW Q LCD The electronic PREMASREG® 716x pressure sensor and switch features measuring functions for volume flow, differential pressure, filter monitoring and liquid level detection based on pressure measurement in clean air. The device has a housing made of... Log in for pricing Compare
Quick view S+S | sku: 2004-6132-4100-021 PREMASREG 7161-UW Q LCD The electronic PREMASREG® 716x pressure sensor and switch features measuring functions for volume flow, differential pressure, filter monitoring and liquid level detection based on pressure measurement in clean air. The device has a housing made of... Log in for pricing Compare
Quick view RESI | sku: RESI-S16DI8PO-SIO BIG IO module, 8TE, module with 16 digital inputs for 12-48V= signals and 8 bistablerelays. contact rating: max. 250Vac, 16A, 200?F, RS485, MODBUS/RTU slave, ASCII text commands, 12-48V= MODBUS/RTU or ASCII module to control socket-outlets, light applications and capacitive loads, with 8 bistable relays (max 250Vac, max. 16A, max. 200?F) and with 16 digital inputs for 12-48Vdc signals via serial bus, switchable loads: Incandescent lamp 4... Log in for pricing Compare
Quick view S+S | sku: 1201-9226-1400-282 HYGRASGARD® FSFTM-Modbus P The HYGRASGARD® FSFTM - Modbus room sensor and measuring transducer with in-wall enclosure and optional potentiometer is used to measure the relative humidity and temperature of the air, and for setpoint adjustment. The following parametres are... Log in for pricing Compare
Quick view Details S+S | sku: 2003-6122-1100-001 HYGRASGARD® AFTF-20-U Q LCD Log in for pricing Compare
Quick view Details S+S | sku: 2003-6122-2100-001 HYGRASGARD® AFTF-20-I Q LCD Log in for pricing Compare
Quick view Details S+S | sku: 2003-4172-1100-001 HYGRASGARD® KFTF-20-U Q LCD Log in for pricing Compare
Quick view Details S+S | sku: 2003-4172-2100-001 HYGRASGARD® KFTF-20-I Q LCD Log in for pricing Compare
Quick view Details S+S | sku: 1301-4122-0560-000 PREMASGARD® SHD 692-I-930 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4122-0550-000 PREMASGARD® SHD 692-I-919 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4122-0540-000 PREMASGARD® SHD 692-I-918 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4122-0530-000 PREMASGARD® SHD 692-I-916 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4122-0520-000 PREMASGARD® SHD 692-I-912 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4122-0510-000 PREMASGARD® SHD 692-I-907 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4122-0500-000 PREMASGARD® SHD 692-I-900 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4121-0560-000 PREMASGARD® SHD 692-U-930 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4121-0550-000 PREMASGARD® SHD 692-U-919 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4121-0540-000 PREMASGARD® SHD 692-U-918 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4121-0530-000 PREMASGARD® SHD 692-U-916 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4121-0520-000 PREMASGARD® SHD 692-U-912 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4121-0510-000 PREMASGARD® SHD 692-U-907 Log in for pricing Compare
Quick view Details S+S | sku: 1301-4121-0500-000 PREMASGARD® SHD 692-U-900 Log in for pricing Compare
Quick view Details RESI | sku: RESI-ENO-ETH Ethernet gateway ENOCEAN-868MHz-MODBUS/TCP server,ASCII text socket, 10/100MBit Ethernet, incl. antenna, EU Log in for pricing Compare
Quick view Details RESI | sku: RESI-12AOU-SIO BIG IO module, 8TE, module with 12 analogue inputs for -10Vdc..+10Vdc or 0..10Vdc voltage signals, RS485, MODBUS/RTU slave, ASCII text commands, 12-48V= Log in for pricing Compare
Quick view Details S+S | sku: 1201-1276-1000-101 HYGRASGARD® RPFTF-20-Modbus Log in for pricing Compare
Quick view Details S+S | sku: 1201-1276-1200-000 HYGRASGARD® RPFTF-Modbus LCD Log in for pricing Compare
Quick view Details S+S | sku: 1201-624F-1000-000 HYGRASGARD® RPFTF-wModbus Log in for pricing Compare
Quick view Details RESI | sku: RESI-8RTD-SIO BIG IO module, 8TE, module with 8 temperature inputs for RTD sensor elements: PT100, PT200, PT500, PT1000, NI120, NI1000-DIN43760. 2 wire, 3 wire or 4 wire connection of sensorelement, RS485, MODBUS/RTU slave, ASCII text commands, 12-48V= Log in for pricing Compare
Quick view Details RESI | sku: RESI-8SB-SIO BIG IO module, 8TE, module for 8 shutters or blinds, RS485, MODBUS/RTU slave, 12-48V= Log in for pricing Compare
Quick view Details RESI | sku: RESI-S16DI8PO-SIO BIG IO module, 8TE, module with 16 digital inputs for 12-48V= signals and 8 bistablerelays. contact rating: max. 250Vac, 16A, 200?F, RS485, MODBUS/RTU slave, ASCII text commands, 12-48V= Log in for pricing Compare
Quick view Details S+S | sku: 1201-9226-1400-282 HYGRASGARD® FSFTM-Modbus P Log in for pricing Compare